Sign In | Join Free | My chinaqualitylighting.com |
|
Brand Name : Fluke
Model Number : 5101B
MOQ : 1
Payment Terms : L/C,D/A,D/P,T/T,Western Union,Western Union,T/T,MoneyGram
Delivery Time : 3-5 days
New / Used : Used
Functions / Ranges : DC/AC Voltage to 1100 V, DC/AC Current to 2 A, Resistance 1 Ω–10 MΩ (4-wire below 2–1100 V). With Model 5220A, current extends to 20 A.
DC Voltage Accuracy (6 months, 20–30 °C) : ±(0.005% of setting + 0.001% of range + 5 µV); ripple/noise ≤0.05% of setting rms.
AC Voltage Accuracy : 50 Hz–10 kHz ±(0.05% of setting + 50 µV); 10–50 kHz up to 110 V ±(0.08% of setting + 80 µV). Wideband Option -03 extends ACV to 10 MHz with specified flatness.
Current Accuracy : DC ±(0.025% of setting + 0.0025% of range + 0.01 µA); AC 50 Hz–1 kHz ±(0.07% of setting + 0.01% of range + 0.02 µA).
Resistance Accuracy (6 months) : 1 Ω 0.02%, 10 Ω 0.01%, 1 kΩ 0.005%, 100 kΩ 0.01%, 1 MΩ 0.01%, 10 MΩ 0.05%.
The Fluke 5101B is a 4.5-digit class multifunction calibrator widely used for DMM and instrument calibration. It sources precision DC/AC volts to 1100 V, DC/AC current to 2 A, and resistance from 1 Ω to 10 MΩ, with remote 4-wire sensing and guarded outputs for low uncertainty. Six-month DCV accuracy is 0.005% with low noise; ACV delivers 0.05% to 10 kHz, and Option -03 provides characterized performance to 10 MHz. Optional GPIB or RS-232 enables automated procedures, and pairing with the 5220A extends current to 20 A. Available second-hand, it offers strong value with calibration on request.
Interested in an Fluke 5101B or a similar model?
Drop your WhatsApp number or e-mail on our website and we will:
Send a tailored quotation and any current promotions.
Provide extra photos, test data, and full configuration details.
Discuss shipping, duties, warranty, and any other specifics you need.
Looking for other models? Our inventory changes daily—ask for the latest list of spectrum analyzers and RF equipment.
Every unit is calibrated at an ISO/IEC 17025 accredited laboratory. The original calibration certificate, marked TESTRO Certified, is linked to the unit’s serial number and included in the shipment.
A set of high-resolution teardown photographs showing seals, fasteners, and all critical modules.
A live video session in which an engineer demonstrates gain-linearity, noise-floor, and spurious-response tests in real time.
All recordings remain in our cloud archive for the life of the product.
We accept T/T, wire transfer, credit card.
Customers are welcome to visit our Shenzhen warehouse and refurbishment line to inspect calibration benches, burn-in racks, and inventory.
![]() |
Fluke 5101B 1100 V / 2 A Multifunction Calibrator With 0.005% DC Accuracy Images |